UniFi networking

UniFi Protect · UniFi Talk · Critical update

UniFi Protect and Talk critical update: patch Bulletin 067 before you do anything else

First published 9 November 2026 · Updated on 10 November 2026 · Every version number below was read from Ubiquiti’s own Security Advisory Bulletin 067 and the CVE records Ubiquiti itself published as CNA — not from a round-up. Where a number comes from anyone else, the article says so.

Merroway Editorial · Verified against governing standards and vendor documentation.

Two of these flaws need no login and no click from you. Ubiquiti’s Bulletin 067 (26 August 2026) discloses 22 flaws across the UniFi range. Three score the maximum, CVSS 10.0 — and two of them sit in the applications this guide is about: CVE-2026-77537 in UniFi Protect and CVE-2026-77554 in UniFi Talk. Anyone who can reach the application over the network can run commands on the host device. The fix is a version number, and this guide is the check-then-patch order that actually closes them.
THREE FLAWS AT 10.0 — THREE FIXES, ONE ORDER 1 · PATCH FIRST UniFi OS Server CVE-2026-77550 CRLF → auth bypass Fixed: 5.1.37 or later 2 · THEN PROTECT UniFi Protect CVE-2026-77537 Command injection Fixed: 7.2.105 or later 3 · THEN TALK UniFi Talk CVE-2026-77554 Command injection Fixed: 5.3.2 or later The order matters: the OS flaw is an authentication bypass. Patching Protect while the bypass is still open leaves the front door unlocked. OS first — then Protect — then Talk — then verify every number below. All three: network-reachable, low complexity, no privileges, no user interaction.
Do this: patch in the numbered order — OS, Protect, Talk — and read every version back afterwards. A patched application on an unpatched OS is a half-finished job. Diagram drawn by Merroway. Numbers: 1 — UniFi OS Server, CVE-2026-77550, fixed in 5.1.37 or later; 2 — UniFi Protect, CVE-2026-77537, fixed in 7.2.105 or later; 3 — UniFi Talk, CVE-2026-77554, fixed in 5.3.2 or later. All three carry CVSS 10.0.

The fast answer

Open your console, go to Settings → Control Plane → Updates, and read the installed version on each row. You are patched only when all three read at or above their fixed version:

  • UniFi OS — 5.1.37 or later on UniFi OS Server; 5.1.31 or later on most consoles (Dream Machines, Cloud Gateways, NVRs, Cloud Keys); 5.1.32 or later on NAS (Enterprise NAS takes 5.1.31, with the consoles); 4.0.17 or later on UniFi Express (Express 7 takes 5.1.31, with the consoles). The number depends on your hardware — see Fix 2.
  • UniFi Protect — 7.2.105 or later (fixes CVE-2026-77537).
  • UniFi Talk — 5.3.2 or later (fixes CVE-2026-77554).

Patch in this order: back up, UniFi OS first, then Protect, then Talk. Do not assume auto-update has done it — log in and look at the numbers. Then work the rest of the bulletin (Fix 5) and the exposure check (Fix 6), because Bulletin 067 is 22 flaws, not three.

What you are looking at, in plain words

On 26 August 2026 Ubiquiti published Security Advisory Bulletin 067, disclosing 22 vulnerabilities across the UniFi product line — the operating system, the Protect, Network, Access, Talk and Connect applications, and peripheral hardware such as the Protect AI Key. Three of the 22 score CVSS 10.0, the top of the scale, and 21 of the 22 score 9.0 or above (Censys’s reading of the bulletin; the lowest is CVE-2026-77538 at 8.2).

CVSS 10.0 means the worst combination the scale can express: the flaw is reachable over the network, it is low-complexity to exploit, it needs no account and no click from anyone. The two flaws in this guide’s title are both the same kind of defect — improper input validation (CWE-20) — which Ubiquiti’s own CVE records describe in identical words: “A malicious actor with access to the network could exploit an Improper Input Validation vulnerability found in UniFi Protect [or Talk] Application to execute a Command Injection on the host device.” In plain words: a stranger who can reach the application can send it a crafted request and get the console itself to run their commands.

The third 10.0 is CVE-2026-77550 in UniFi OS Server — a CRLF-injection flaw that lets an unauthenticated attacker bypass authentication on the console. It is in this guide because it changes the patch order: an authentication bypass makes the bulletin’s other flaws chainable, so the OS goes first even though the title leads with Protect and Talk.

Two facts that should shape your urgency, both dated: as of Censys’s check on 28 August 2026, no public proof-of-concept existed for any Bulletin 067 flaw, and none of the 22 appeared in the CISA Known Exploited Vulnerabilities catalog — no exploitation had been reported. That is a snapshot from August, not a promise about November. Patch while the window is still quiet.

Step 0 — Prove which part is failing

There is nothing to diagnose here in the usual sense — no error message, no log line. The only question is a version number, and the only wrong move is guessing it. Read all three rows before you update anything, and write them down: the “before” numbers are what prove the “after” numbers later.

Where each version lives — read, don’t guess (field map drawn by Merroway)
Open1open the console — Site Manager at unifi.ui.com, the local console address, or the UniFi mobile app
Go to2Settings → Control Plane → Updates — one row per console and per application
Read3read the installed version on the UniFi Console row, the Protect row and the Talk row
Compare4compare each one against the fixed versions in the table below — below means vulnerable, whatever the update badge says
Write down5write down all three “before” numbers now; the proof step at the end needs them
Do this: read the three rows and write them down before any update — a fix you cannot measure afterwards is a hope, not a repair. Field map drawn by Merroway; the Updates path is Ubiquiti’s own (Help Center troubleshooting guides). Numbers: 1 — open the console; 2 — Settings → Control Plane → Updates; 3 — read the three rows; 4 — compare against the fixed versions; 5 — write the “before” numbers down.
ProductVulnerable versionsFixed version (or later)Flaw
UniFi Protect Application7.1.87 and earlier7.2.105CVE-2026-77537 — unauthenticated command injection, CVSS 10.0
UniFi Talk Application5.2.7 and earlier5.3.2CVE-2026-77554 — unauthenticated command injection, CVSS 10.0
UniFi OS Server (self-hosted)5.1.21 and earlier5.1.37CVE-2026-77550 — CRLF authentication bypass, CVSS 10.0
UniFi OS on consoles (Dream Machines, Cloud Gateways, NVRs, Cloud Keys, Dream Wall, Express 7)5.1.26 and earlier5.1.31CVE-2026-77550 and related OS flaws
UniFi OS on NAS5.1.26 and earlier5.1.32CVE-2026-77550 and related OS flaws
UniFi Express4.0.16 and earlier4.0.17CVE-2026-77550 and related OS flaws

The fixed UniFi OS version depends on your hardware family — that is the bulletin’s own structure, not a simplification. Do not apply one OS number fleet-wide: a Dream Machine takes 5.1.31, a self-hosted OS Server takes 5.1.37, a NAS takes 5.1.32, and an Express takes 4.0.17. Three refinements inside the OS numbers: Enterprise NAS belongs to the 5.1.31 group, not the 5.1.32 NAS line, and the 5.1.31 group also covers the enterprise models the table does not name — Enterprise NVRs, Enterprise Firewall Core, Dream Routers and Enterprise Fortress Gateway — and UniFi Express 7 belongs to the 5.1.31 group, not the 4.0.17 Express line: Express and Express 7 are different products on different version lines. The Protect and Talk numbers do not vary: 7.2.105 and 5.3.2, everywhere.

Fix 1 — Back up before you touch anything

  1. Go to Settings → Control Plane → Backups. This is the same Control Plane area as the Updates page, one menu over.
  2. Download an offline backup and store it somewhere other than the console itself. If System Backups (cloud) is switched on, the console already makes a cloud backup weekly and before each major update, saved to the owner’s UI account — but for this job, take your own downloadable copy too, so the rollback file is in your hands, not only in the cloud.
  3. Do it before the OS update, not after. The OS update is the step that reboots the box that routes your traffic; a backup taken after a bad update is a backup of the bad state.

If you run Protect on a console that is also your gateway, tell the site first: the OS update below takes the network down for a few minutes. A camera site that cannot tolerate a gap should be patched in a quiet window, not at midday.

Fix 2 — Update UniFi OS first

  1. On the Updates page, open the UniFi Console row (Settings → Control Plane → Updates). Ubiquiti’s own troubleshooting order is the same: update UniFi OS first, then the application.
  2. Apply the update for your hardware family — 5.1.37 for UniFi OS Server, 5.1.31 for most consoles, 5.1.32 for NAS, 4.0.17 for UniFi Express (Express 7 takes 5.1.31). If the row offers a newer version than the fixed one, take the newer one: “or later” is the bulletin’s own wording.
  3. Wait for the console to come back. An OS update reboots the device — the network, Protect and Talk go down with it for a few minutes. Do not power-cycle it mid-reboot, and do not start the application updates until the console is fully back and the dashboard loads cleanly.
  4. Re-read the console row. It must now show at or above your family’s fixed version. If it does not, stop here — work the ladder at the end of this guide before touching Protect or Talk.
Do not skip this fix because you “only run Protect”. The OS flaw is an authentication bypass. Patching Protect while the bypass is open leaves an unauthenticated route onto the same console — the applications are not separate fortresses, they share the box.
Advertisements

Fix 3 — Update Protect to 7.2.105 or later

  1. On the same Updates page, open the UniFi Protect Application row.
  2. Apply the update to 7.2.105 or later. This one update also closes two further Protect flaws in the same bulletin — CVE-2026-77533 and CVE-2026-77548, both CVSS 9.9 command-injection flaws that need only a low-privileged account — so it is worth more than the single headline CVE.
  3. Wait for Protect to come back, then open it. Cameras should reappear as they reconnect; a camera that stays offline after the console is healthy is a separate problem — see the ladder below, and the Protect adoption guide linked in Sources.
  4. Re-read the Protect row. It must show 7.2.105 or above. Anything below is still vulnerable to CVE-2026-77537, whatever the update badge said.

Fix 4 — Update Talk to 5.3.2 or later

  1. On the same Updates page, open the UniFi Talk Application row. If Talk is not installed on your console, there is no row and nothing to do here — skip to Fix 5.
  2. Apply the update to 5.3.2 or later.
  3. Wait for Talk to come back, then check the phones. Talk phones should re-register; a phone that stays unregistered after the application is healthy is a separate problem — see the ladder below.
  4. Re-read the Talk row. It must show 5.3.2 or above. Anything below is still vulnerable to CVE-2026-77554.

Talk is the smallest of the three updates and the easiest to forget — it is also the one with the fewest internet-facing hosts, which is no comfort if yours is one of them. Patch it on the same visit, not “next time”.

Fix 5 — Sweep the rest of the bulletin

Bulletin 067 is 22 flaws, and the three 10.0s are only the headline. The same Updates page lists the rest of the applications — check each row against its fixed version while you are already there. Every fix below was available on the day the bulletin was published, 26 August 2026.

ProductFixed version (or later)Why it is on your list
UniFi Network Application10.5.67High-privilege command-injection and access-control flaws in the same bulletin
UniFi Access Application4.3.5Low-privilege command-injection and privilege-escalation flaws (CVSS 9.9)
UniFi Connect Application3.24.22Unauthenticated privilege escalation (CVE-2026-77538, CVSS 8.2) and related flaws
UID Enterprise Agent1.62.1High-privilege command injection in the same bulletin
Protect AI Key2.2.6Unauthenticated flaw, CVSS 9.8 (CVE-2026-77557)
Connect Display Cast Pro1.0.111Unauthenticated flaw, CVSS 9.0 (CVE-2026-77551)
Enterprise Audio/Video Bridge1.0.11Unauthenticated flaw, CVSS 9.8 (CVE-2026-77552)

Only patch what is installed — an application you do not run has no row and needs nothing. But check every row that exists: the bulletin’s authenticated flaws are exactly the ones an attacker reaches after the OS bypass, so leaving a 9.9 unpatched next to a patched 10.0 is not a completed job.

Fix 6 — Close the front door, and stop relying on luck

Patching closes these 22 flaws. It does not close the next bulletin. Two settings decide how much the next one can hurt you, and both live on pages you have already opened:

  1. Take the management interface off the open internet. Put console management behind a VPN or an IP allowlist, or use Ubiquiti’s remote-access service instead of a directly reachable address. These flaws are network-reachable by design — “reachable” is the whole attack, so shrinking who can reach the console is the highest-value step after patching itself.
  2. Turn on automatic updates for the console and the applications (Settings → Control Plane → Updates, per console and per application). Bulletin 067’s fixes were all available on disclosure day; the gap that matters next time is the gap between release and install. If auto-update is not right for a production site, set it to notify-only and treat the notification as a same-day job — do not let it sit in an inbox.
  3. Repeat the version read at every site you manage. Site Manager (unifi.ui.com) gives a consolidated view across sites once signed in — use it, rather than assuming a site you have not opened is patched because another one is.

Prove it worked

A patched console looks exactly like an unpatched one from the outside. The proof is the numbers — read them again, in the same place, and compare against the “before” numbers you wrote down in Step 0.

Prove it worked — read every number back (field map drawn by Merroway)
Check1UniFi OS row — at or above your hardware family’s fixed version (5.1.37 Server / 5.1.31 consoles incl. Express 7 / 5.1.32 NAS / 4.0.17 Express)
Check2Protect row — 7.2.105 or above, and no update offered for Protect
Check3Talk row — 5.3.2 or above (or no Talk row, because Talk is not installed)
Check4Every other application row — at or above its Fix 5 version, or no update offered
Check5Protect opens and cameras are live — live view works and the timeline plays back a minute recorded after the update
Check6Talk phones re-registered — each phone shows registered, and a test call connects
Check7Write the “after” numbers down — next to the “before” numbers, same page, same day
Do this: read all six rows back and run the two live checks — a version number you re-read is proof; an update badge you trusted is not. Field map drawn by Merroway; the versions it names come from Ubiquiti’s bulletin. Numbers: 1 — UniFi OS at its fixed version; 2 — Protect 7.2.105 or above; 3 — Talk 5.3.2 or above; 4 — every other application at its fixed version; 5 — Protect live and playing back; 6 — Talk phones registered with a test call; 7 — write the “after” numbers down.
Advertisements

Still not working? Work this ladder in order

  1. No update is offered, but the version is below the fixed one. Ubiquiti rolls releases out in stages, so a fix can exist without having reached your console yet. Check the release channel on the Updates page is Official, not Early Access — and do not switch a production console to Early Access to chase a security fix. Check again later the same day, and again the next day; if it still has not appeared after that, open Ubiquiti’s Bulletin 067 release post and follow the per-product release link for your hardware family.
  2. The console row shows a different fixed version than this guide. Trust the bulletin over this guide: the OS fix is 5.1.37 for OS Server, 5.1.31 for most consoles (including Enterprise NAS, Express 7 and the enterprise gateways), 5.1.32 for NAS and 4.0.17 for Express. Confirm which hardware family your console belongs to before deciding the number is wrong.
  3. The update downloads but fails, or the console will not come back. Do not keep re-pushing the update. Work the UniFi firmware-update failure guide first — UniFi firmware update failed: recovery — which covers the documented failure order, including the recovery-mode gate. If the console is a gateway as well as a recorder, the site is offline until it returns: say so out loud before you start the next step.
  4. Protect updated but a camera stays offline. That is an adoption problem, not a patch problem — the update did not cause it, it exposed it. Work Protect camera won’t adopt — or adopts and records nothing for that camera only, and do not roll Protect back to “fix” a camera.
  5. The new Protect or Talk build misbehaves after updating. UniFi OS 5.1.12 and later lets you revert an application to its previous version from the Updates page. Revert only to restore service, then re-apply the patch as soon as the replacement build is available — running the vulnerable version as a permanent answer is not a fix. (This revert capability is reported in third-party UniFi OS documentation of the 5.1.12 release; it was not re-verified on Ubiquiti’s own pages for this guide — see Sources.)
  6. A Talk phone will not register after the update. Check the phone is on the same network the console can reach, and that Talk itself shows the patched version — a phone cannot register to an application that has not finished coming back. If Talk is patched and the phone still will not register, treat it as a Talk setup problem, not a bulletin problem, and work it phone by phone.
  7. Nothing above fits. Download a support file before anything destructive — in the application, Settings → Control Plane → Console → Support File → Full → Download — and take it to Ubiquiti Support with your before/after version numbers. The numbers are the whole diagnosis; without them, support starts from zero.

Mistakes that make it worse

MistakeWhy it hurts
Patching only Protect and stoppingThe OS authentication bypass (CVE-2026-77550) stays open on the same console, and the bulletin’s authenticated flaws are reachable through it. Patch OS first, then the applications.
Trusting auto-update without lookingA setting that is supposed to have updated and a device that actually updated are not the same thing. Read the version rows back — that is the whole proof step.
Applying one UniFi OS version number fleet-wideThe fixed OS version differs by hardware family (5.1.37 / 5.1.31 / 5.1.32 / 4.0.17). A Dream Machine on 5.1.37 or an OS Server on 5.1.31 is the wrong build for that box.
Port-forwarding the console to the internet “so I can check it remotely”These flaws are network-reachable by design. A forwarded management interface is the attack surface itself — use a VPN, an allowlist, or Ubiquiti’s remote-access service instead.
Reading “no evidence of exploitation” as “safe to wait”The no-evidence statement is dated 28 August 2026, and it says nothing about November. Quiet is a window, not a verdict.
Updating in the middle of the working day with no backupThe OS update reboots the box that routes the site’s traffic and runs its cameras and phones. A quiet window plus a downloaded backup costs minutes; a midday failure costs the site.
Rolling Protect back to the old version to “fix” a cameraThe old version is the vulnerable version. A camera that stays offline after the patch is an adoption problem — fix the camera, not the patch.
Third-party side note — not Ubiquiti’s numbers. Censys scanned the internet the day after disclosure, 27 August 2026, and counted 102,607 hosts exposing a UniFi OS management interface, 828 exposing UniFi Protect and 10 exposing UniFi Talk. Censys itself stresses these are exposed hosts, not confirmed-unpatched ones — UniFi OS does not disclose its version to an unauthenticated request, so the scan cannot say which of those hosts were vulnerable. The numbers are included only to show the exposure exists; they prove nothing about your console. What proves something about your console is Step 0.

FAQ

I only run Protect — do I still need the UniFi OS and Talk updates?

UniFi OS, yes — patch it first. Its flaw (CVE-2026-77550) is an authentication bypass, and it is the flaw that makes the rest of the bulletin chainable, so Protect alone is not a complete fix. Talk only matters if the Talk application is installed on your console; if it is not installed, there is nothing to patch there.

My console says no update is available. Am I already patched?

Only the version numbers can answer that. Open Settings, then Control Plane, then Updates, and read the installed version on each row: UniFi OS at or above your hardware family’s fixed version, Protect at 7.2.105 or above, Talk at 5.3.2 or above. If a row is below its fixed version and no update is offered, Ubiquiti rolls releases out in stages, so check again later — and check the release channel is Official, not Early Access.

Has anyone actually been attacked through these flaws?

No evidence of exploitation had been reported when Censys checked on 28 August 2026: no public proof-of-concept existed for any Bulletin 067 flaw, and none of the 22 appeared in the CISA Known Exploited Vulnerabilities catalog. That is a snapshot from August, not a promise about November — it is a reason to patch now, while the window is still quiet, not a reason to wait.

Do the cameras and phones need updating too?

Bulletin 067’s fixes are application and operating-system versions, not camera or phone firmware — Protect 7.2.105, Talk 5.3.2 and the UniFi OS build for your hardware. Once the applications are patched, check the Devices page for any pending camera or phone firmware and apply it on its own schedule; it is a separate track, not part of this bulletin.

Sources

Ubiquiti — Security Advisory Bulletin 067, published 26 August 2026 (bulletin number, date, the 22-flaw count, affected and fixed versions) · CVE Program, Ubiquiti as CNA — CVE-2026-77537 (UniFi Protect Application, affected below 7.2.105, CVSS 10.0) · CVE-2026-77554 (UniFi Talk Application, affected below 5.3.2, CVSS 10.0) · CVE-2026-77550 (UniFi OS Server, affected below 5.1.37, CVSS 10.0) · Ubiquiti Help Center — Troubleshooting UniFi Access Device Adoption Issue and Troubleshooting UniFi Access Device Offline Issue (Settings → Control Plane → Updates; update UniFi OS first, then the application) · Ubiquiti Help Center — Backups and Migration in UniFi (Settings → Control Plane → Backups; System Backups weekly and before major updates) · Censys — August 28 Advisory: Ubiquiti Security Advisory Bulletin Discloses 21 Critical Vulnerabilities (per-hardware-family fixed versions, the 21-of-22 at 9.0-or-above split, no public proof-of-concept, no evidence of exploitation as of 28 August 2026, exposure counts, patch-OS-first remediation order, remove-management-from-the-internet recommendation). Related Merroway guides: UniFi firmware update failed: recovery · Protect camera won’t adopt — or adopts and records nothing.

Verification note: the CVE numbers, products, affected ranges, fixed versions and CVSS 10.0 scores were confirmed on 9 November 2026 against the CVE records Ubiquiti published as CNA and the search-indexed text of Ubiquiti’s own Bulletin 067 page, and re-confirmed on 10 November 2026 by a fresh pull of all 22 CVE records (including the Express 7 = 5.1.31 bound in the CVE-2026-77550 record itself) — Ubiquiti’s community pages return only a script shell to this pass’s tooling, so the bulletin was read through its search index and cross-checked against Censys’s bulletin-linked version table. Honest limits, printed rather than hidden: the Help Center “Backups and Migration” page was read directly on 9 November 2026 and confirms the backup path and the weekly / before-major-update cloud schedule; the application-revert capability (UniFi OS 5.1.12 and later) is reported in third-party UniFi OS documentation and is labelled as such in the ladder; the exposure counts are a third-party scan, fenced in their own box; no genuine screenshots exist for this guide — every visual is a drawn map or diagram, labelled as such — because no console access was available; and the “no evidence of exploitation” claim is dated 28 August 2026 — a fresh pull of the CISA Known Exploited Vulnerabilities catalog on 10 November 2026 still lists none of the 22, but the article does not extend the claim past that check.